Uninsulated Wire Data Chart
|
Uninsulated Wire Data by Wire Type |
|||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
Wire Type |
|||||||||||
|
Alloy |
Electrolytic Tough Pitch (ETP) Copper (C11000) |
Electrolytic Tough Pitch (ETP) Copper (C11000), Tin-Plated |
SAE 316L |
Nichrome 80 |
|||||||
|
Chemical |
99.90% Cu Min., 0.04% O |
99.90% Cu Min., 0.04% O, plus Sn coating |
16‑18% Cr, 10‑14% Ni, 2‑3% Mo, 2% Mn, 1% Si, Other Trace Elements, Bal. Fe |
80% Ni, 20% Cr |
|||||||
|
Density |
0.323 lb/in³ |
0.323 lb/in³ plus tin |
0.289 lb/in³ |
0.304 lb/in³ |
|||||||
|
Yield Strength |
12,000 psi |
12,000 psi |
20,000 – 40,000 psi |
— |
|||||||
|
Tensile Strength |
34,000 psi |
34,000 psi |
85,000 – 115,000 psi |
100,000 psi |
|||||||
|
Operating |
— |
150°C (302°F) |
925°C (1697°F) |
1177°C (2150°F) |
|||||||
|
Approx. |
1981°C (3598°F) |
232°C (450°F) |
1400°C (2552°F) |
1400°C (2552°F) |
|||||||
|
AWG |
Diameter 1 |
DCR at 20°C |
Weight (lb/1000 ft) |
DCR at 20°C |
Weight |
DCR at 20°C |
Weight |
DCR at 20°C |
Weight |
||
|
Resistance & Weight by AWG |
14 |
0.0641" |
|||||||||
|
16 |
0.0508" |
||||||||||
|
18 |
0.0403" |
||||||||||
|
20 |
0.0320" |
||||||||||
|
22 |
0.0254" |
||||||||||
|
24 |
0.0201" |
||||||||||
|
26 |
0.0159" |
||||||||||
|
28 |
0.0126" |
||||||||||
|
30 |
0.0100" |
||||||||||
|
32 |
0.0080" |
176.7 |
0.194 |
||||||||
|
34 |
0.0063" |
281.1 |
0.121 |
16.3523 |
0.1139 |
||||||
|
36 |
0.0050" |
447.1 |
0.0757 |
26.0013 |
0.0716 |
||||||
|
38 |
0.0040" |
659.6 |
0.0484 |
711.0 |
0.0484 |
41.3438 |
0.0450 |
||||
|
40 |
0.0031" |
1049 |
0.0291 |
1130.9 |
0.0300 |
65.7394 |
0.0283 |
||||
|
42 |
0.0025" |
1652 |
0.0189 |
1789.9 |
0.0189 |
104.5301 |
0.0178 |
||||
|
44 |
0.0020" |
2589 |
0.0121 |
2845.5 |
0.0121 |
166.2098 |
0.0112 |
||||
Click any number in red to view the webpage for that standard Remington Industries product.
1 These dimensions are provided for reference. The actual diameter for a given wire type can slightly vary by different materials and other factors. See our product pages to determine nominal values.
All values are nominal unless otherwise specified.
Uninsulated Wire Data Sheets
Bare & Tinned Copper Wire Data Sheet
Nichrome 80 Wire Data Sheet
Stainless Steel 316L Wire Data Sheet
↑ End of section
Contact Us
Still wondering how to read wire data, or how to find a wire size? Learning about wire gauge sizes, figuring out what size wire you need and browsing different types of wire with their specifications can be a challenge.
If you can’t find the wire size chart you’re looking for or have additional questions about wire data, contact our friendly team; we’re here to make understanding wire gauge sizes easy.
Contact us by phone: (815) 385-1987
Contact us by email: sales@remingtonindustries.com | Contact Form
Mailing Address:
3521 N. Chapel Hill Road
Johnsburg, IL 60051 U.S.A.